Reverse osmosis membranes are often described as the “heart” of a filtration system. If that’s true, a 40/40 RO membrane is one of the most common hearts beating away in residential, light commercial and small industrial installations. Yet most users know surprisingly little about how these membranes actually perform, how to optimise them, or what to expect in terms of PFAS removal.

This guide walks through the performance of 40/40 RO membranes in practical terms: what they are, how they work, what affects their efficiency, and how to run them in a way that delivers reliable contaminant removal – including PFAS – without wasting water or energy.

What exactly is a 40/40 RO membrane?

A “40/40” RO membrane is a standard spiral-wound element with:

This format is widely used in:

Inside the pressure vessel, feed water flows across the membrane surface. Under pressure, water molecules pass through the semi-permeable polyamide layer, while most dissolved salts, organic molecules and many PFAS are rejected and stay in the concentrate (waste) stream.

Because of their size and flow capacity, 40/40 elements often serve as a bridge between small under-sink units and large 8-inch industrial membranes. They’re compact, relatively affordable, and can be arranged in arrays to scale up treatment capacity.

Key performance metrics you should watch

To manage a 40/40 membrane effectively, you need to track a few core performance indicators. These are the numbers that tell you whether your membrane is healthy, efficient, and actually protecting users from contaminants such as PFAS.

1. Permeate flow rate (flux)

Permeate flow is simply the volume of treated water produced, usually expressed as:

Typical 40/40 membranes for brackish water or tap-water polishing are often rated around 2,000–2,500 GPD at specific test conditions (e.g., 25°C, 150 psi, 2,000 ppm NaCl). Real-world values are often lower because:

Monitoring permeate flow over time is crucial. A slow, steady drop usually indicates fouling or scaling. A sudden jump can mean a damaged membrane – which is bad news for PFAS and other contaminant removal.

2. Salt rejection (and why it matters for PFAS)

Salt rejection (%) indicates how effectively the membrane blocks dissolved ions:

Rejection = (1 – (Permeate TDS / Feed TDS)) × 100

For a healthy 40/40 RO element treating relatively low-salinity feed, you might expect 96–99% salt rejection under normal operating conditions.

While PFAS are not “salts” in the traditional sense, high salt rejection usually correlates with good overall membrane integrity and structure. If salt rejection drops significantly, you should assume other contaminants – including PFAS – may be slipping through as well.

3. Recovery rate

Recovery is the percentage of feed water that becomes permeate:

Recovery (%) = (Permeate flow / Feed flow) × 100

Higher recovery means less wastewater, which is attractive in terms of water efficiency. But push recovery too high and you concentrate salts, organics and PFAS on the membrane surface, increasing fouling, scaling and the risk of performance loss.

Typical recovery for single 40/40 elements often sits around 35–50%, depending on feed quality and pre-treatment. Multi-element arrays can be designed for higher system-wide recovery with careful staging.

4. Differential pressure (ΔP)

ΔP is the pressure drop from inlet to outlet on the feed/concentrate side. It’s a direct indicator of hydraulic resistance inside the element. A rising ΔP usually means:

Each manufacturer will give a baseline ΔP and a threshold increase (e.g., 15% or 1 bar over baseline) at which you should consider cleaning. Ignoring ΔP trends is a fast way to shorten a membrane’s life and lose PFAS removal efficiency.

What affects 40/40 membrane performance in practice?

Even the best membrane element is only as good as the conditions you operate it under. Four variables dominate performance: feed water quality, pressure, temperature and pH.

Feed water quality

Feed water is rarely just “water plus a few salts”. In real installations, it can contain:

Pre-treatment is therefore critical. For a 40/40 RO, good practice usually includes:

Where PFAS are a concern, upstream granular activated carbon (GAC) can also help reduce the PFAS load on the membrane and improve long-term stability.

Pressure

Applying pressure is how RO “pushes” water through the membrane against the osmotic gradient. For a 40/40 element treating relatively low-salinity groundwater or municipal water, operating pressures often fall between 8–16 bar (120–230 psi), depending on design.

Under-pressure reduces permeate flow and can compromise rejection if flux drops below the membrane’s optimal range. Over-pressure increases energy consumption and can risk compaction or mechanical damage.

The performance sweet spot is generally where:

Temperature

Warmer water is less viscous and passes through the membrane more easily. As a rule of thumb, every 3°C increase in temperature can raise permeate flow by roughly 7–10%, but salt rejection may drop slightly.

Winter versus summer feed temperatures can therefore significantly change your apparent “membrane performance” even if the membrane itself has not changed at all. Temperature correction factors from the manufacturer are essential when interpreting data.

pH

Most polyamide RO membranes are designed for a pH operating range of around 2–11, but long-term operation is typically kept between pH 3–10 for membrane longevity.

pH affects:

Careful pH control during both operation and cleaning can significantly extend the life of a 40/40 element.

PFAS removal with 40/40 RO membranes

Can a 40/40 membrane remove PFAS effectively? In many cases, yes – particularly the longer-chain compounds like PFOA and PFOS. But the details matter.

What the evidence shows

Peer-reviewed studies and field data generally indicate:

RO membranes reject PFAS mainly through size exclusion and electrostatic interactions. Long-chain PFAS are larger and tend to be more strongly rejected, while some short-chain PFAS are small enough to partially slip through.

Why membrane health is critical for PFAS control

Partially damaged or fouled membranes can show:

In PFAS-sensitive applications (e.g., drinking water, lab water), relying on a single barrier is inherently risky. Good practice often includes:

If a 40/40 RO membrane is part of your PFAS strategy, you should treat its performance monitoring as a non-negotiable safety measure rather than a maintenance nicety.

Operating a 40/40 system for efficiency and stability

Good design is only half the story. Day-to-day operation determines whether your 40/40 RO runs quietly in the background or becomes a constant source of problems.

Set realistic recovery targets

Running a single 40/40 element at 75–80% recovery might look efficient on paper, but in practice it can lead to rapid scaling and fouling unless feed water is exceptionally clean. For most users:

Protect the membrane from oxidants

Standard polyamide RO membranes are highly sensitive to free chlorine and other oxidants. Even low levels over time can cause irreversible damage, reducing rejection and increasing PFAS breakthrough risk.

That’s why an upstream activated carbon filter or dechlorination step is essential when treating chlorinated municipal feed water.

Stabilise operation – avoid shocks

Rapid pressure changes, sudden stops and starts, and frequent shutdowns can all stress the membrane and its spacers. Where possible:

Monitoring, diagnostics and troubleshooting

Well-run systems treat monitoring as part of normal operation, not a last resort when something fails.

Parameters to log regularly

From these, you can calculate:

What common symptoms usually mean

Cleaning and maintenance of 40/40 membranes

Even well-designed systems will eventually foul. Proper cleaning and maintenance extend the useful life of 40/40 elements and help maintain PFAS removal efficiency.

When to clean

Most manufacturers recommend cleaning when:

Waiting until performance has halved is not cost-effective; advanced fouling is harder to reverse and may permanently damage the membrane.

Types of cleaning

Cleaning protocols must respect the membrane’s pH, temperature and exposure limits. Overly aggressive conditions can strip away performance along with the fouling.

Storage and preservation

If a 40/40 membrane will be idle for more than a few days, you should:

Poor storage is a common reason for “mysterious” performance loss in otherwise new or lightly used membranes.

End-of-life, waste streams and PFAS responsibility

A 40/40 membrane may seem small in the context of global PFAS contamination, but how you handle it – and its brine – still matters.

Dealing with PFAS-rich concentrate

RO does not destroy PFAS; it concentrates them in the brine stream. Discharging that brine without understanding the regulatory framework and environmental risk simply moves the problem downstream.

Depending on jurisdiction and application, options may include:

Disposal of spent membranes

RO elements are complex composites of plastics, adhesives and mesh materials. Today, most still end up in landfill, where PFAS and other adsorbed contaminants may be a concern.

Some manufacturers and specialised recyclers are developing take-back and recycling programmes for spent RO elements. When available, these options are preferable to simple disposal, especially for membranes used in PFAS treatment.

Ultimately, 40/40 membranes are a powerful tool – but not a magic wand. They are most effective when integrated with thoughtful pre-treatment, downstream safeguards and responsible waste management.

Used well, they can form a robust barrier against a wide range of contaminants, including many PFAS, helping to protect both human health and aquatic ecosystems. Used carelessly, they risk giving a false sense of security while quietly shifting persistent chemicals from one part of the water cycle to another.

The difference comes down to design, data, and a willingness to look at the whole system – not just the membrane cartridge inside the pressure vessel.